| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130 |
- /*
- Navicat SQL Server Data Transfer
- Source Server : 9000
- Source Server Version : 105000
- Source Host : .\sqlexpress:1433
- Source Database : LHBMS
- Source Schema : dbo
- Target Server Type : SQL Server
- Target Server Version : 105000
- File Encoding : 65001
- Date: 2021-05-11 15:33:06
- */
- -- ----------------------------
- -- Table structure for Device
- -- ----------------------------
- DROP TABLE [dbo].[Device]
- GO
- CREATE TABLE [dbo].[Device] (
- [ID] uniqueidentifier NOT NULL DEFAULT (newid()) ROWGUIDCOL ,
- [Name] nvarchar(50) NOT NULL ,
- [SN] nvarchar(50) NULL ,
- [DevTypeID] uniqueidentifier NULL ,
- [IPAddress] nvarchar(50) NULL ,
- [Port] int NULL DEFAULT ((0)) ,
- [Status] tinyint NULL DEFAULT ((0)) ,
- [Location] nvarchar(50) NULL ,
- [Telphone] nvarchar(50) NULL ,
- [Owner] nvarchar(50) NULL ,
- [OrgzID] uniqueidentifier NULL ,
- [Deployer] nvarchar(50) NULL ,
- [DeployerPhone] nvarchar(50) NULL ,
- [DeployUnit] nvarchar(50) NULL ,
- [DeployDate] datetime NULL ,
- [Remark] nvarchar(100) NULL ,
- [CommType] tinyint NOT NULL DEFAULT ((0)) ,
- [ComNo] int NULL ,
- [BaudRate] int NULL
- )
- GO
- IF ((SELECT COUNT(*) from fn_listextendedproperty('MS_Description',
- 'SCHEMA', N'dbo',
- 'TABLE', N'Device',
- 'COLUMN', N'SN')) > 0)
- EXEC sp_updateextendedproperty @name = N'MS_Description', @value = N'主机序列号'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'SN'
- ELSE
- EXEC sp_addextendedproperty @name = N'MS_Description', @value = N'主机序列号'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'SN'
- GO
- IF ((SELECT COUNT(*) from fn_listextendedproperty('MS_Description',
- 'SCHEMA', N'dbo',
- 'TABLE', N'Device',
- 'COLUMN', N'Status')) > 0)
- EXEC sp_updateextendedproperty @name = N'MS_Description', @value = N'0:离线 ,1:在线'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'Status'
- ELSE
- EXEC sp_addextendedproperty @name = N'MS_Description', @value = N'0:离线 ,1:在线'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'Status'
- GO
- IF ((SELECT COUNT(*) from fn_listextendedproperty('MS_Description',
- 'SCHEMA', N'dbo',
- 'TABLE', N'Device',
- 'COLUMN', N'Owner')) > 0)
- EXEC sp_updateextendedproperty @name = N'MS_Description', @value = N'负责人'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'Owner'
- ELSE
- EXEC sp_addextendedproperty @name = N'MS_Description', @value = N'负责人'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'Owner'
- GO
- IF ((SELECT COUNT(*) from fn_listextendedproperty('MS_Description',
- 'SCHEMA', N'dbo',
- 'TABLE', N'Device',
- 'COLUMN', N'DeployUnit')) > 0)
- EXEC sp_updateextendedproperty @name = N'MS_Description', @value = N'安装单位'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'DeployUnit'
- ELSE
- EXEC sp_addextendedproperty @name = N'MS_Description', @value = N'安装单位'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'DeployUnit'
- GO
- IF ((SELECT COUNT(*) from fn_listextendedproperty('MS_Description',
- 'SCHEMA', N'dbo',
- 'TABLE', N'Device',
- 'COLUMN', N'CommType')) > 0)
- EXEC sp_updateextendedproperty @name = N'MS_Description', @value = N'0: IP 1: Com'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'CommType'
- ELSE
- EXEC sp_addextendedproperty @name = N'MS_Description', @value = N'0: IP 1: Com'
- , @level0type = 'SCHEMA', @level0name = N'dbo'
- , @level1type = 'TABLE', @level1name = N'Device'
- , @level2type = 'COLUMN', @level2name = N'CommType'
- GO
- -- ----------------------------
- -- Records of Device
- -- ----------------------------
- -- ----------------------------
- -- Indexes structure for table Device
- -- ----------------------------
- -- ----------------------------
- -- Primary Key structure for table Device
- -- ----------------------------
- ALTER TABLE [dbo].[Device] ADD PRIMARY KEY ([ID])
- GO
|